Nova PM Sensor SDS011 Datasheet
Component DatasheetNova PM Sensor SDS011 Datasheet
The Nova PM Sensor, SDS011 is an extremely ongoing Air Quality Sensor created by Nova Fitness. It deals with the guideline of laser dispersing and can get the molecule focus between 0.3 to 10μm noticeable all around.
This sensor comprises a little fan, air channel and source valve, laser diode, and photodiode. It works with an ostensible 4.7V to a limit of 5.3 VDC supply voltage.
Be that as it may, it normally works with 5.0V DC voltage and requires a limit of 100mA current. This sensor accompanies the going with a link and 'USB to chronic converter' for associating the sensor to a PC straightforwardly if necessary.
Pin Description of SDS011 Sensor
Pin No.
Pin Name
Description
1
NC
Not Connected
2
1µm
PM2.5: 0-999μg/m³; PWM Output
3
5V
5V Input
4
2.5μm
PM10: 0-999 μg/m³; PWM Output
5
GND
Ground Pin
6
RXD
Receiver of UART(TTL)@3.3V
7
TXD
Transmitter of UART(TTL)@3.3V
Features and Specification of SDS011 SensorOutput: PM2.5, PM10
Measuring Range: 0.0-999.9μg/m3
Input Voltage: 4.7V to 5.3V
Maximum Current: 100mA
Sleep Current: 2mA
Response Time: 1 second
Serial Data Output Frequency: 1 time/second
Particle Diameter Resolution: ≤0.3μm
Relative Error: 10%
Temperature Range: -20~50°C
Accurate and Reliable: laser detection, stable, good consistency
Easy integration: UART output (or IO output can be customized), fan built-in
Note: Complete technical details can be found in the SDS011 Sensor Datasheet linked at the bottom of this page.
Alternative for SDS011 SensorPM2.5 GP2Y1010AU0F Dust Smoke Particle Sensor
DSM501A PM2.5 Dust Sensor
SDS011 Sensor - Overview
The Nova PM sensor is designed with a built-in fan to ensure proper air circulation to a chamber with a laser diode, where the size and amount of PM are determined. As mentioned earlier, it works on the principle of laser scattering.
Pin Description of SDS011 Sensor
Pin No.
Pin Name
Description
1
NC
Not Connected
2
1µm
PM2.5: 0-999μg/m³; PWM Output
3
5V
5V Input
4
2.5μm
PM10: 0-999 μg/m³; PWM Output
5
GND
Ground Pin
6
RXD
Receiver of UART(TTL)@3.3V
7
TXD
Transmitter of UART(TTL)@3.3V
Features and Specification of SDS011 SensorOutput: PM2.5, PM10
Measuring Range: 0.0-999.9μg/m3
Input Voltage: 4.7V to 5.3V
Maximum Current: 100mA
Sleep Current: 2mA
Response Time: 1 second
Serial Data Output Frequency: 1 time/second
Particle Diameter Resolution: ≤0.3μm
Relative Error: 10%
Temperature Range: -20~50°C
Accurate and Reliable: laser detection, stable, good consistency
Easy integration: UART output (or IO output can be customized), fan built-in
Note: Complete technical details can be found in the SDS011 Sensor Datasheet linked at the bottom of this page.
Alternative for SDS011 SensorPM2.5 GP2Y1010AU0F Dust Smoke Particle Sensor
DSM501A PM2.5 Dust Sensor
SDS011 Sensor - Overview
The Nova PM sensor is designed with a built-in fan to ensure proper air circulation to a chamber with a laser diode, where the size and amount of PM are determined. As mentioned earlier, it works on the principle of laser scattering.
The air enters through the air inlet where a light source (Laser) illuminates the particles and the scattered light is transformed into a signal by a photodetector. These signals are then amplified and processed to get the particle concentration of PM2.5 and PM10. The laser diode used in this sensor is a high-quality diode and its service life is up to 8000 hours.
Applications of SDS011 SensorPM2.5, PM10 Detector
Purifier
Air Exchangers
Filtering system
2D and Dimensions of SDS011 Sensor
Applications of SDS011 SensorPM2.5, PM10 Detector
Purifier
Air Exchangers
Filtering system